123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194 |
- #pragma once
- #include <AP_Common/AP_Common.h>
- #include <AP_Param/AP_Param.h>
- #include <AP_Math/AP_Math.h>
- #include <GCS_MAVLink/GCS_MAVLink.h>
- #include "AP_BattMonitor_Params.h"
- // maximum number of battery monitors
- #define AP_BATT_MONITOR_MAX_INSTANCES 9
- // first monitor is always the primary monitor
- #define AP_BATT_PRIMARY_INSTANCE 0
- #define AP_BATT_SERIAL_NUMBER_DEFAULT -1
- #define AP_BATT_MONITOR_TIMEOUT 5000
- #define AP_BATT_MONITOR_RES_EST_TC_1 0.5f
- #define AP_BATT_MONITOR_RES_EST_TC_2 0.1f
- // declare backend class
- class AP_BattMonitor_Backend;
- class AP_BattMonitor_Analog;
- class AP_BattMonitor_SMBus;
- class AP_BattMonitor_SMBus_Solo;
- class AP_BattMonitor_SMBus_Maxell;
- class AP_BattMonitor_UAVCAN;
- class AP_BattMonitor
- {
- friend class AP_BattMonitor_Backend;
- friend class AP_BattMonitor_Analog;
- friend class AP_BattMonitor_SMBus;
- friend class AP_BattMonitor_SMBus_Solo;
- friend class AP_BattMonitor_SMBus_Maxell;
- friend class AP_BattMonitor_UAVCAN;
- friend class AP_BattMonitor_Sum;
- friend class AP_BattMonitor_FuelFlow;
- friend class AP_BattMonitor_FuelLevel_PWM;
- public:
- // battery failsafes must be defined in levels of severity so that vehicles wont fall backwards
- enum BatteryFailsafe {
- BatteryFailsafe_None = 0,
- BatteryFailsafe_Low,
- BatteryFailsafe_Critical
- };
- FUNCTOR_TYPEDEF(battery_failsafe_handler_fn_t, void, const char *, const int8_t);
- AP_BattMonitor(uint32_t log_battery_bit, battery_failsafe_handler_fn_t battery_failsafe_handler_fn, const int8_t *failsafe_priorities);
- /* Do not allow copies */
- AP_BattMonitor(const AP_BattMonitor &other) = delete;
- AP_BattMonitor &operator=(const AP_BattMonitor&) = delete;
- static AP_BattMonitor *get_singleton() {
- return _singleton;
- }
- struct cells {
- uint16_t cells[MAVLINK_MSG_BATTERY_STATUS_FIELD_VOLTAGES_LEN];
- };
- // The BattMonitor_State structure is filled in by the backend driver
- struct BattMonitor_State {
- cells cell_voltages; // battery cell voltages in millivolts, 10 cells matches the MAVLink spec
- float voltage; // voltage in volts
- float current_amps; // current in amperes
- float consumed_mah; // total current draw in milliamp hours since start-up
- float consumed_wh; // total energy consumed in Wh since start-up
- uint32_t last_time_micros; // time when voltage and current was last read in microseconds
- uint32_t low_voltage_start_ms; // time when voltage dropped below the minimum in milliseconds
- uint32_t critical_voltage_start_ms; // critical voltage failsafe start timer in milliseconds
- float temperature; // battery temperature in degrees Celsius
- uint32_t temperature_time; // timestamp of the last received temperature message
- float voltage_resting_estimate; // voltage with sag removed based on current and resistance estimate in Volt
- float resistance; // resistance, in Ohms, calculated by comparing resting voltage vs in flight voltage
- BatteryFailsafe failsafe; // stage failsafe the battery is in
- bool healthy; // battery monitor is communicating correctly
- bool is_powering_off; // true when power button commands power off
- bool powerOffNotified; // only send powering off notification once
- };
- // Return the number of battery monitor instances
- uint8_t num_instances(void) const { return _num_instances; }
- // detect and initialise any available battery monitors
- void init();
- /// Read the battery voltage and current for all batteries. Should be called at 10hz
- void read();
- // healthy - returns true if monitor is functioning
- bool healthy(uint8_t instance) const;
- bool healthy() const { return healthy(AP_BATT_PRIMARY_INSTANCE); }
- /// voltage - returns battery voltage in millivolts
- float voltage(uint8_t instance) const;
- float voltage() const { return voltage(AP_BATT_PRIMARY_INSTANCE); }
- /// get voltage with sag removed (based on battery current draw and resistance)
- /// this will always be greater than or equal to the raw voltage
- float voltage_resting_estimate(uint8_t instance) const;
- float voltage_resting_estimate() const { return voltage_resting_estimate(AP_BATT_PRIMARY_INSTANCE); }
- /// current_amps - returns the instantaneous current draw in amperes
- bool current_amps(float ¤t, const uint8_t instance = AP_BATT_PRIMARY_INSTANCE) const WARN_IF_UNUSED;
- /// consumed_mah - returns total current drawn since start-up in milliampere.hours
- bool consumed_mah(float &mah, const uint8_t instance = AP_BATT_PRIMARY_INSTANCE) const WARN_IF_UNUSED;
- /// consumed_wh - returns total energy drawn since start-up in watt.hours
- bool consumed_wh(float&wh, const uint8_t instance = AP_BATT_PRIMARY_INSTANCE) const WARN_IF_UNUSED;
- /// capacity_remaining_pct - returns the % battery capacity remaining (0 ~ 100)
- virtual uint8_t capacity_remaining_pct(uint8_t instance) const;
- uint8_t capacity_remaining_pct() const { return capacity_remaining_pct(AP_BATT_PRIMARY_INSTANCE); }
- /// pack_capacity_mah - returns the capacity of the battery pack in mAh when the pack is full
- int32_t pack_capacity_mah(uint8_t instance) const;
- int32_t pack_capacity_mah() const { return pack_capacity_mah(AP_BATT_PRIMARY_INSTANCE); }
-
- /// returns true if a battery failsafe has ever been triggered
- bool has_failsafed(void) const { return _has_triggered_failsafe; };
- /// returns the highest failsafe action that has been triggered
- int8_t get_highest_failsafe_priority(void) const { return _highest_failsafe_priority; };
- /// get_type - returns battery monitor type
- enum AP_BattMonitor_Params::BattMonitor_Type get_type() const { return get_type(AP_BATT_PRIMARY_INSTANCE); }
- enum AP_BattMonitor_Params::BattMonitor_Type get_type(uint8_t instance) const { return _params[instance].type(); }
- /// true when (voltage * current) > watt_max
- bool overpower_detected() const;
- bool overpower_detected(uint8_t instance) const;
- // cell voltages
- bool has_cell_voltages() { return has_cell_voltages(AP_BATT_PRIMARY_INSTANCE); }
- bool has_cell_voltages(const uint8_t instance) const;
- const cells & get_cell_voltages() const { return get_cell_voltages(AP_BATT_PRIMARY_INSTANCE); }
- const cells & get_cell_voltages(const uint8_t instance) const;
- // temperature
- bool get_temperature(float &temperature) const { return get_temperature(temperature, AP_BATT_PRIMARY_INSTANCE); };
- bool get_temperature(float &temperature, const uint8_t instance) const;
- // get battery resistance estimate in ohms
- float get_resistance() const { return get_resistance(AP_BATT_PRIMARY_INSTANCE); }
- float get_resistance(uint8_t instance) const { return state[instance].resistance; }
- // returns false if we fail arming checks, in which case the buffer will be populated with a failure message
- bool arming_checks(size_t buflen, char *buffer) const;
- // sends powering off mavlink broadcasts and sets notify flag
- void checkPoweringOff(void);
- // reset battery remaining percentage
- bool reset_remaining(uint16_t battery_mask, float percentage);
- static const struct AP_Param::GroupInfo var_info[];
- protected:
- /// parameters
- AP_BattMonitor_Params _params[AP_BATT_MONITOR_MAX_INSTANCES];
- private:
- static AP_BattMonitor *_singleton;
- BattMonitor_State state[AP_BATT_MONITOR_MAX_INSTANCES];
- AP_BattMonitor_Backend *drivers[AP_BATT_MONITOR_MAX_INSTANCES];
- uint32_t _log_battery_bit;
- uint8_t _num_instances; /// number of monitors
- void convert_params(void);
- /// returns the failsafe state of the battery
- BatteryFailsafe check_failsafe(const uint8_t instance);
- void check_failsafes(void); // checks all batteries failsafes
- battery_failsafe_handler_fn_t _battery_failsafe_handler_fn;
- const int8_t *_failsafe_priorities; // array of failsafe priorities, sorted highest to lowest priority, -1 indicates no more entries
- int8_t _highest_failsafe_priority; // highest selected failsafe action level (used to restrict what actions we move into)
- bool _has_triggered_failsafe; // true after a battery failsafe has been triggered for the first time
- };
- namespace AP {
- AP_BattMonitor &battery();
- };
|