# Compatibility of MMDetection 2.x
## MMDetection 2.25.0
In order to support Mask2Former for instance segmentation, the original config files of Mask2Former for panpotic segmentation need to be renamed [PR #7571](https://github.com/open-mmlab/mmdetection/pull/7571).
before v2.25.0 |
after v2.25.0 |
```
'mask2former_xxx_coco.py' represents config files for **panoptic segmentation**.
```
|
```
'mask2former_xxx_coco.py' represents config files for **instance segmentation**.
'mask2former_xxx_coco-panoptic.py' represents config files for **panoptic segmentation**.
```
|
## MMDetection 2.21.0
In order to support CPU training, the logic of scatter in batch collating has been changed. We recommend to use
MMCV v1.4.4 or higher. For more details, please refer to [MMCV PR #1621](https://github.com/open-mmlab/mmcv/pull/1621).
## MMDetection 2.18.1
### MMCV compatibility
In order to fix the wrong weight reference bug in BaseTransformerLayer, the logic in batch first mode of MultiheadAttention has been changed.
We recommend to use MMCV v1.3.17 or higher. For more details, please refer to [MMCV PR #1418](https://github.com/open-mmlab/mmcv/pull/1418).
## MMDetection 2.18.0
### DIIHead compatibility
In order to support QueryInst, attn_feats is added into the returned tuple of DIIHead.
## MMDetection 2.14.0
### MMCV Version
In order to fix the problem that the priority of EvalHook is too low, all hook priorities have been re-adjusted in 1.3.8, so MMDetection 2.14.0 needs to rely on the latest MMCV 1.3.8 version. For related information, please refer to [#1120](https://github.com/open-mmlab/mmcv/pull/1120), for related issues, please refer to [#5343](https://github.com/open-mmlab/mmdetection/issues/5343).
### SSD compatibility
In v2.14.0, to make SSD more flexible to use, [PR5291](https://github.com/open-mmlab/mmdetection/pull/5291) refactored its backbone, neck and head. The users can use the script `tools/model_converters/upgrade_ssd_version.py` to convert their models.
```bash
python tools/model_converters/upgrade_ssd_version.py ${OLD_MODEL_PATH} ${NEW_MODEL_PATH}
```
- OLD_MODEL_PATH: the path to load the old version SSD model.
- NEW_MODEL_PATH: the path to save the converted model weights.
## MMDetection 2.12.0
MMDetection is going through big refactoring for more general and convenient usages during the releases from v2.12.0 to v2.18.0 (maybe longer).
In v2.12.0 MMDetection inevitably brings some BC-breakings, including the MMCV dependency, model initialization, model registry, and mask AP evaluation.
### MMCV Version
MMDetection v2.12.0 relies on the newest features in MMCV 1.3.3, including `BaseModule` for unified parameter initialization, model registry, and the CUDA operator `MultiScaleDeformableAttn` for [Deformable DETR](https://arxiv.org/abs/2010.04159). Note that MMCV 1.3.2 already contains all the features used by MMDet but has known issues. Therefore, we recommend users to skip MMCV v1.3.2 and use v1.3.2, though v1.3.2 might work for most of the cases.
### Unified model initialization
To unify the parameter initialization in OpenMMLab projects, MMCV supports `BaseModule` that accepts `init_cfg` to allow the modules' parameters initialized in a flexible and unified manner. Now the users need to explicitly call `model.init_weights()` in the training script to initialize the model (as in [here](https://github.com/open-mmlab/mmdetection/blob/main/tools/train.py#L162), previously this was handled by the detector. **The downstream projects must update their model initialization accordingly to use MMDetection v2.12.0**. Please refer to PR #4750 for details.
### Unified model registry
To easily use backbones implemented in other OpenMMLab projects, MMDetection v2.12.0 inherits the model registry created in MMCV (#760). In this way, as long as the backbone is supported in an OpenMMLab project and that project also uses the registry in MMCV, users can use that backbone in MMDetection by simply modifying the config without copying the code of that backbone into MMDetection. Please refer to PR #5059 for more details.
### Mask AP evaluation
Before [PR 4898](https://github.com/open-mmlab/mmdetection/pull/4898) and V2.12.0, the mask AP of small, medium, and large instances is calculated based on the bounding box area rather than the real mask area. This leads to higher `APs` and `APm` but lower `APl` but will not affect the overall mask AP. [PR 4898](https://github.com/open-mmlab/mmdetection/pull/4898) change it to use mask areas by deleting `bbox` in mask AP calculation.
The new calculation does not affect the overall mask AP evaluation and is consistent with [Detectron2](https://github.com/facebookresearch/detectron2/).
## Compatibility with MMDetection 1.x
MMDetection 2.0 goes through a big refactoring and addresses many legacy issues. It is not compatible with the 1.x version, i.e., running inference with the same model weights in these two versions will produce different results. Thus, MMDetection 2.0 re-benchmarks all the models and provides their links and logs in the model zoo.
The major differences are in four folds: coordinate system, codebase conventions, training hyperparameters, and modular design.
### Coordinate System
The new coordinate system is consistent with [Detectron2](https://github.com/facebookresearch/detectron2/) and treats the center of the most left-top pixel as (0, 0) rather than the left-top corner of that pixel.
Accordingly, the system interprets the coordinates in COCO bounding box and segmentation annotations as coordinates in range `[0, width]` or `[0, height]`.
This modification affects all the computation related to the bbox and pixel selection,
which is more natural and accurate.
- The height and width of a box with corners (x1, y1) and (x2, y2) in the new coordinate system is computed as `width = x2 - x1` and `height = y2 - y1`.
In MMDetection 1.x and previous version, a "+ 1" was added both height and width.
This modification are in three folds:
1. Box transformation and encoding/decoding in regression.
2. IoU calculation. This affects the matching process between ground truth and bounding box and the NMS process. The effect to compatibility is very negligible, though.
3. The corners of bounding box is in float type and no longer quantized. This should provide more accurate bounding box results. This also makes the bounding box and RoIs not required to have minimum size of 1, whose effect is small, though.
- The anchors are center-aligned to feature grid points and in float type.
In MMDetection 1.x and previous version, the anchors are in `int` type and not center-aligned.
This affects the anchor generation in RPN and all the anchor-based methods.
- ROIAlign is better aligned with the image coordinate system. The new implementation is adopted from [Detectron2](https://github.com/facebookresearch/detectron2/tree/master/detectron2/layers/csrc/ROIAlign).
The RoIs are shifted by half a pixel by default when they are used to cropping RoI features, compared to MMDetection 1.x.
The old behavior is still available by setting `aligned=False` instead of `aligned=True`.
- Mask cropping and pasting are more accurate.
1. We use the new RoIAlign to crop mask targets. In MMDetection 1.x, the bounding box is quantized before it is used to crop mask target, and the crop process is implemented by numpy. In new implementation, the bounding box for crop is not quantized and sent to RoIAlign. This implementation accelerates the training speed by a large margin (~0.1s per iter, ~2 hour when training Mask R50 for 1x schedule) and should be more accurate.
2. In MMDetection 2.0, the "`paste_mask()`" function is different and should be more accurate than those in previous versions. This change follows the modification in [Detectron2](https://github.com/facebookresearch/detectron2/blob/master/detectron2/structures/masks.py) and can improve mask AP on COCO by ~0.5% absolute.
### Codebase Conventions
- MMDetection 2.0 changes the order of class labels to reduce unused parameters in regression and mask branch more naturally (without +1 and -1).
This effect all the classification layers of the model to have a different ordering of class labels. The final layers of regression branch and mask head no longer keep K+1 channels for K categories, and their class orders are consistent with the classification branch.
- In MMDetection 2.0, label "K" means background, and labels \[0, K-1\] correspond to the K = num_categories object categories.
- In MMDetection 1.x and previous version, label "0" means background, and labels \[1, K\] correspond to the K categories.
- **Note**: The class order of softmax RPN is still the same as that in 1.x in versions\<=2.4.0 while sigmoid RPN is not affected. The class orders in all heads are unified since MMDetection v2.5.0.
- Low quality matching in R-CNN is not used. In MMDetection 1.x and previous versions, the `max_iou_assigner` will match low quality boxes for each ground truth box in both RPN and R-CNN training. We observe this sometimes does not assign the most perfect GT box to some bounding boxes,
thus MMDetection 2.0 do not allow low quality matching by default in R-CNN training in the new system. This sometimes may slightly improve the box AP (~0.1% absolute).
- Separate scale factors for width and height. In MMDetection 1.x and previous versions, the scale factor is a single float in mode `keep_ratio=True`. This is slightly inaccurate because the scale factors for width and height have slight difference. MMDetection 2.0 adopts separate scale factors for width and height, the improvement on AP ~0.1% absolute.
- Configs name conventions are changed. MMDetection V2.0 adopts the new name convention to maintain the gradually growing model zoo as the following:
```shell
[model]_(model setting)_[backbone]_[neck]_(norm setting)_(misc)_(gpu x batch)_[schedule]_[dataset].py,
```
where the (`misc`) includes DCN and GCBlock, etc. More details are illustrated in the [documentation for config](tutorials/config)
- MMDetection V2.0 uses new ResNet Caffe backbones to reduce warnings when loading pre-trained models. Most of the new backbones' weights are the same as the former ones but do not have `conv.bias`, except that they use a different `img_norm_cfg`. Thus, the new backbone will not cause warning of unexpected keys.
### Training Hyperparameters
The change in training hyperparameters does not affect
model-level compatibility but slightly improves the performance. The major ones are:
- The number of proposals after nms is changed from 2000 to 1000 by setting `nms_post=1000` and `max_num=1000`.
This slightly improves both mask AP and bbox AP by ~0.2% absolute.
- The default box regression losses for Mask R-CNN, Faster R-CNN and RetinaNet are changed from smooth L1 Loss to L1 loss. This leads to an overall improvement in box AP (~0.6% absolute). However, using L1-loss for other methods such as Cascade R-CNN and HTC does not improve the performance, so we keep the original settings for these methods.
- The sample num of RoIAlign layer is set to be 0 for simplicity. This leads to slightly improvement on mask AP (~0.2% absolute).
- The default setting does not use gradient clipping anymore during training for faster training speed. This does not degrade performance of the most of models. For some models such as RepPoints we keep using gradient clipping to stabilize the training process and to obtain better performance.
- The default warmup ratio is changed from 1/3 to 0.001 for a more smooth warming up process since the gradient clipping is usually not used. The effect is found negligible during our re-benchmarking, though.
### Upgrade Models from 1.x to 2.0
To convert the models trained by MMDetection V1.x to MMDetection V2.0, the users can use the script `tools/model_converters/upgrade_model_version.py` to convert
their models. The converted models can be run in MMDetection V2.0 with slightly dropped performance (less than 1% AP absolute).
Details can be found in `configs/legacy`.
## pycocotools compatibility
`mmpycocotools` is the OpenMMlab's fork of official `pycocotools`, which works for both MMDetection and Detectron2.
Before [PR 4939](https://github.com/open-mmlab/mmdetection/pull/4939), since `pycocotools` and `mmpycocotool` have the same package name, if users already installed `pycocotools` (installed Detectron2 first under the same environment), then the setup of MMDetection will skip installing `mmpycocotool`. Thus MMDetection fails due to the missing `mmpycocotools`.
If MMDetection is installed before Detectron2, they could work under the same environment.
[PR 4939](https://github.com/open-mmlab/mmdetection/pull/4939) deprecates mmpycocotools in favor of official pycocotools.
Users may install MMDetection and Detectron2 under the same environment after [PR 4939](https://github.com/open-mmlab/mmdetection/pull/4939), no matter what the installation order is.